Archives

  • 2018-07
  • 2018-10
  • 2018-11
  • 2019-04
  • 2019-05
  • 2019-06
  • 2019-07
  • 2019-08
  • 2019-09
  • 2019-10
  • 2019-11
  • 2019-12
  • 2020-01
  • 2020-02
  • 2020-03
  • 2020-04
  • 2020-05
  • 2020-06
  • 2020-07
  • 2020-08
  • 2020-09
  • 2020-10
  • 2020-11
  • 2020-12
  • 2021-01
  • 2021-02
  • 2021-03
  • 2021-04
  • 2021-05
  • 2021-06
  • 2021-07
  • 2021-08
  • 2021-09
  • 2021-10
  • 2021-11
  • 2021-12
  • 2022-01
  • 2022-02
  • 2022-03
  • 2022-04
  • 2022-05
  • 2022-06
  • 2022-07
  • 2022-08
  • 2022-09
  • 2022-10
  • 2022-11
  • 2022-12
  • 2023-01
  • 2023-02
  • 2023-03
  • 2023-04
  • 2023-05
  • 2023-06
  • 2023-07
  • 2023-08
  • 2023-09
  • 2023-10
  • 2023-11
  • 2023-12
  • 2024-01
  • 2024-02
  • 2024-03
  • 2024-04
  • br Data CMP experiments were performed on the titanium plate

    2018-11-14


    Data CMP experiments were performed on the titanium plates by altering the sample surface through various CMP conditions [1]. First, slurry particle size and stability were evaluated through particle light scattering based particle size measurement by using Coulter LS 13 320 equipment as can be seen in Fig. 1. Contact angle measurements (wettability) and root mean square (RMS) surface roughness values were measured by contact angle goniometer and atomic force microscopy (AFM), respectively and summarized in Fig. 2. Furthermore, surface chemical compositions of the titanium samples were studied through FT-IR analyses to observe any chemical changes on the surface layer as seen in Fig. 3.
    Experimental design, materials and methods Titanium foils with 1mm thickness and 99.6% purity (TI000430) were obtained from Goodfellow Cambridge Ltd. Initial samples were polished by using Suba IV subpad stacked under a polytex buff pad to obtain a smooth surface finish while protecting macro scale surface contours of the implants. In addition, two different sizes of abrasive papers (silicon carbide 150C-90µm particle size and P320- 45µm particle size) were used in place of the polishing pad to create the microstructures through CMP. CMP slurries were prepared by using 5wt% alumina (Al2O3) abrasives with 50nm particle size at pH 4 using nitric acid. Slurry stability and particle size distribution was studied by using Coulter LS 13 320 laser particle size measurement instrument. Titanium samples were polished for 2minutes in the presence of 3wt% H2O2 in the solution (H2O2- Sigma Aldrich, %34.5–36.5 purity) as an oxidizer to promote the chemical activity. Material removal rates were calculated through weighing the samples pre and post CMP. All samples were cleaned in ultrasonic bath by using pH adjusted DI water for 5min and dried with nitrogen gas before they were characterized. Fig. 1 shows the particle size distribution of the CMP slurries based on volume and number based distributions. It can be seen that the baseline slurry has a bimodal size distribution due to the agglomerates present in the slurry. The volume based size distribution measurements highlight the agglomerates better as the orexin agonist manufacturer particulate volume normalizes the data. Yet, the number based particle size distribution results show that the number percentage distribution of the agglomerates at 2-micrometer size range is negligible within the overall slurry particle population. Before the application of CMP, original baseline titanium plates had a thick anodized oxide layer on the surface. CMP process performed in the absence of an oxidizer resulted in removal of this porous top oxide layer and exposed the bare titanium surface with a ~45 degree contact angle value, which is approximately half of the contact angle value measured on the untreated baseline sample. The remaining sample plates were CMP treated in the presence of an oxidizer in the polishing slurry. As megakarocytes can be seen in Fig. 2, the change in surface roughness had a more predominant effect on the wettability, which is measured by contact angle response. Contact angle values increased as a function of surface roughness on these samples exposed to CMP (excluding the baseline sample with porous oxide on top). The highest contact angle value was obtained on the untreated baseline titanium sample, which can be attributed to the porosity of the surface oxide [2]. Fig. 2-b compares the change in the material removal rate responses by RMS surface roughness measurements obtained through AFM analyses. It can be seen that both the material removal rate and the surface roughness increases when the CMP is conducted by using abrasive papers in place of the original polytex based polishing pad material. The surface optical images also highlight the induced surface microstructures when the rough fixed abrasive polishing papers are utilized during the CMP. Fig. 3 illustrates the surface chemical composition evaluations obtained by FT-IR analyses. The IR spectrum of both the CMP implemented and the baseline samples show a transmittance peak at ~550cm−1 corresponding to the characteristic peak of Ti-O vibration in TiO2[3]. The change in the peak intensity as a function of the implemented CMP treatment highlights the impact of CMP process on the surface oxide film formation. The original sample has the highest peak due to the presence of thick oxide layer. Around the 1100cm−1 wavenumber, the broader peak is assigned to the Ti–O–H bond vibration on the surface [4]. The transmittance peak at ~626cm−1 in the spectrum belongs to the peaks of Ti–O stretching [5]. In all the analyzed peaks, the highest intensity remains to be on the baseline sample due to its thick anodized oxide layer as compared to the nano-scale thin oxide film formation on the samples prepared by CMP implementation.